Stainless Steel Intake Doors: 1 1/2 hour "B" temperature rise - 30 minutes -650 degree max. *Underwriters Laboratory Test #R15927, tested and approved for masonry and/or non-masonry walls.
*New York Board of Standards and APPEALS LABEL: MEA #206-96-M
Intake doors are self-closing, positive latching. Fabricated of polished stainless steel front and aluminized steel backs. Steel angle frame with 3-1/2" steel extensions. Integral polished stainless steel trim with top side embossed designating the use of the chute, in English and Braille. Pivot type hinge welded to the door frame. Door equipped with chrome plated key locking "T" handle latching assembly, fire rated locking (with two keys).
Bottom Hinge Intake Doors

Side Hinge Intake Doors
Model # Recommended Use Frame Size into Chute
|
1215-BH
1515-SH
1518-BH
1717-BH
1818-BH
1818-SH
2020-SH
2424-SH |
Trash
Linen, Access
Linen, Trash
Linen, Trash
Linen, Trash
Linen, Trash, Access
Linen, Trash, Access
Linen, Trash, Access |
11 3/4"w x 14 3/4"h
15 1/2"w x 15 1/4"h
14 3/4"w x 17 3/4"h
17 3/4"w x 17 1/2"h
18 1/4"w x 18 1/4"h
17 1/2"w x 17 3/4"h
19 1/2"w x 19 1/4"h
23 1/2"w x 23 3/4"h |
Discharge Fire Rated Doors: Same UL Rated type construction specifications as intake doors above.
"H" type 2430 Outlet (24: Diameter Chutes) 24 1/4"w x 24 1/4"h
Sliding Outlet Doors: (Not fire rated) 16 GA Aluminized Steel construction, with 2" x 2" x 1/4" angle frame, spring loaded. Held open by a 165 degree U.L. fusible link.
"S" Type 24 Standard outlet for 24" diameter chutes.
"SB" Type 24 "B" construction outlet for 24" diameter chutes. Note: Underwriters Laboratories do not offer a test/label for horizontal chute type doors, we manufacture the "SB" under the fire rated design requirements as the intake door panels.

Optional Accessories:
"ADSU": Disinfectant-sanitizer/access door unit can be added to the flush head at the top floor to periodically clean the chute with the proper solution.
Sound Insulation: Factory spray coated with sound dampening material and floor frame isolators.
Thru the Wall Door/Sleeve: to offer service away from the chute shaft.
Rubber or Steel Back Draft Baffles: To minimize the backdrafting out of the chute door.
*We carry an extensive line of replacement parts for all chute doors in use today. Please call for pricing and technical advice*
|
Home |
Products |
Specifications |
Contact chutes, chute, chutes, trash chutes, linen chutes, intakes, Global Metal Solutions, chute manufacturers, discharge doors, vents, outlet doors, ADSU, sound insulation, chute, thru the wall doorsleeve, chutes, rubber back, steel back, chute systems, draft baffles, chute shafts, chute doors, chute replacement parts, chutes, chute door, Global Metal Solutions, rubbish, trash, waste, garbage, metal doors, metal work, chute, chutes, chute |
|